Jump to content
Main menu
Main menu
move to sidebar
hide
Navigation
Main page
Recent changes
Random page
Help about MediaWiki
The Stars Are Right
Search
Search
Appearance
Create account
Log in
Personal tools
Create account
Log in
Pages for logged out editors
learn more
Contributions
Talk
Editing
"do You May Have Difficulty Breathing
Page
Discussion
English
Read
Edit
Edit source
View history
Tools
Tools
move to sidebar
hide
Actions
Read
Edit
Edit source
View history
General
What links here
Related changes
Special pages
Page information
Appearance
move to sidebar
hide
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
<br>FIG. 5 is a script entry display in line with the popular embodiment of the invention. FIG. 6A is an inventory of a pattern script program in line with the popular embodiment of the invention. FIG. 13 is a perspective view of a remotely programmable apparatus in response to an embodiment of the present invention. FIG. 16 is a schematic block diagram illustrating the interaction of the server of FIG. 1A-D with the apparatus of FIG. Three in accordance to another embodiment of the current invention. FIG. 19 is a script entry screen according to an embodiment of the current invention. FIGS. 20 and 21 are block diagrams of alternate embodiments of the current invention. FIGS. 23 and 24 are example broadcast programming displays with an included script program. 16 includes a server 18 and a workstation 20 linked to the server 18 through a communication network 24 . 18 is preferably a world broad net server and the communication network 24 is preferably the Internet.<br><br><br><br>Will probably be obvious to 1 expert in the artwork that the server 18 may comprise a single stand-alone laptop or a number of computers distributed throughout a community. 20 is preferably a personal laptop, remote terminal, or net Tv unit related to the server 18 via the Internet. 20 capabilities as a distant interface for getting into within the server 18 messages and queries to be communicated to the patients. 16 additionally includes multiple remotely programmable apparatus, equivalent to first and second apparatuses 26 for monitoring a number of patients. Each apparatus 26 is designed to interact with a affected person in accordance with script programs obtained from the server 18 . Each apparatus 26 is in communication with the server 18 by way of the communication community 24 , preferably the Internet. 26 may be placed in communication with the server 18 via wireless communication networks, cellular networks, phone networks, satellite networks or [https://xqr.ai/carmellake BloodVitals experience] another network which allows each apparatus 26 to change information with the server 18 .<br><br><br><br>16 might embrace any number of remotely programmable apparatuses for monitoring any number of patients. 28 is designed to produce measurements of a physiological condition of the patient, record the measurements, and transmit the measurements to the patient's remotely programmable apparatus by way of a normal connection cable 30 . 28 embody blood glucose meters, respiratory circulate meters, blood strain cuffs, digital weight scales, and pulse charge screens. Such monitoring gadgets are well known within the artwork. 28 supplied to each patient is dependent upon the patient's illness or well being treatment needs. FIG. 2 reveals the server 18 , the workstation 20 , [https://online-learning-initiative.org/wiki/index.php/Apple_Watch_Series_6:_New_Wearable_Announced_With_Updated_Colours_And_Blood_Oxygen_Sensors BloodVitals SPO2] and the apparatus 26 in larger element. 18 features a database 38 for storing script packages 40 . Forty are executed by every apparatus 26 , to communicate queries and messages to a patient, receive responses 42 to the queries, acquire monitoring machine measurements 44 , and to transmit responses forty two and measurements forty four to the server 18 .<br><br><br><br>38 is designed to store responses 42 and measurements forty four . 38 additional consists of a look-up table 46 . Forty six comprises an inventory of the patients to be monitored, and for each patient, a singular patient identification code and [https://gitea.bastiqui.com/iraschlapp1669 BloodVitals SPO2] a respective pointer to one or more script applications forty assigned to the patient. Each remotely programmable apparatus 26 is designed to execute assigned script packages forty received from the server 18 . 40 might include queries, reminder messages, informational statements, helpful quotations, or other data of benefit to the affected person. See Appendix A for instance script applications. FIG. 3-four show the structure of a remotely programmable apparatus 26 in keeping with the preferred embodiment. 26 includes a housing sixty two . Sixty two is sufficiently compact to enable the apparatus 26 to be hand-held and carried by a affected person. 26 also includes a display sixty four for displaying queries and prompts to the affected person.<br><br><br><br>Sixty four is a liquid crystal show (LCD). 26 contains 5 person input buttons 70 A, 70 B, 70 C, 70 D and 70 E which might be located on the identical aspect of the apparatus 26 because the display 64 . 70 A-D are for getting into in the apparatus 26 responses forty two to the queries and prompts. 70 A-D are momentary contact push buttons. 70 A-D may be replaced by switches, keys, a contact sensitive display screen, or some other data input gadget. 70 E is a emergency or other services button and [https://gitea.oio.cat/jvxedmund84368 painless SPO2 testing] is preferably pink, [https://dev.neos.epss.ucla.edu/wiki/index.php?title=10_Best_Blood_Oxygen_Monitors_For_Coronavirus BloodVitals SPO2] but could also be of any dimension, shape, or shade that pulls particular visual or tactile attention to the consumer. 70 E are described in additional element under. 26 additionally features a modem jack sixty six for connecting the apparatus 26 to a phone jack via a typical connection cord (not proven). 26 further consists of a visible indicator, comparable to a gentle emitting diode (LED) 74 . LED 74 is for visually notifying the patient that she or he has unanswered queries saved in the apparatus 26 .<br>
Summary:
Please note that all contributions to The Stars Are Right may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see
The Stars Are Right:Copyrights
for details).
Do not submit copyrighted work without permission!
Cancel
Editing help
(opens in new window)